Veolia
- Markets:Civil InfrastructureAll projects
- Country:Belgium
Project Description
There was a need to insulate a concrete tunnel at the water treatment plant in Brussels. The objective was to prevent the heating up and expansion of concrete walls (0.30m thickness) after cracks were injected with epoxy mortars against water leakage.
Max temperature allowed: 167°F (75°C)
Temperature hot air inside when in operation: 248°F (120°C)
Air Pressure: 1.2 bar
Air speed in tunnel: 10m/sec
Coating Solution
1st – RUST GRIP at 16 m²/gal
2nd – HOT PIPE COATING at 0.75 m²/gal
3rd – SUPER THERM at 9 m²/gal
Results
Products we used
Our knowledgeable staff is available to answer any questions you may have. Call, text or email us anytime.