Nationwide Shipping
★ Applied Live — No Shutdown · Spray-On Ceramic Insulation to 800°F

HPC Coating

Insulate Hot Pipes — Without Shutting Down

HPC® Coating is a water-based, spray-applied ceramic insulation engineered to control heat transfer on hot pipes, tanks, valves, and ovens — applied while the system stays in operation. No shutdown, no pre-formed sections, no cladding. The ceramic film forms a monolithic, non-conductive block against heat: standard HPC handles surfaces to 390°F, and HPC Intermediate extends the same chemistry to 800°F with a 900°F temporary peak. Non-flammable, non-toxic, lead- and chromate-free, USDA accepted, ABS marine approved. Made in USA.

Live Steam Line Being Sprayed — No Shutdown
HPC® Coating - Live Steam Line Being Sprayed — No Shutdown
Coated Valve & Flange Detail — Sealed Geometry
HPC® Coating - Coated Valve & Flange Detail — Sealed Geometry
Hot Tank Sidewall — Before & After
HPC® Coating - Hot Tank Sidewall — Before & After
HPC Intermediate on Super-Heat Line (390–800°F)
HPC® Coating - HPC Intermediate on Super-Heat Line (390–800°F)
Oven Wall Application — Non-Flammable Formula
HPC® Coating - Oven Wall Application — Non-Flammable Formula
Coated Pipe Rack — Refinery Service
HPC® Coating - Coated Pipe Rack — Refinery Service
HPC® Coating — Ships Nationwide, Non-Hazmat
HPC® Coating — Ships Nationwide, Non-Hazmat

HPC & HPC Intermediate  ·  Authorized SPI Distributor  ·  Ships Nationwide (non-hazmat)

What's Your Surface Temperature?

HPC® Coating selected — specs, calculator, and order form below are set to HPC (to 390°F).

AS
About Arin Shahmoradian
Official USA distributor of Rust Grip® (SPI Coatings). Volta Coatings has shipped Rust Grip to industrial, marine, farm, and residential customers across the United States and internationally for over a decade. Direct technical support before, during, and after every project. Reach him directly at +18186963786 or arin@voltacoatings.com

How Does Spray-On Pipe Insulation Work?

HPC Coating loads specific ceramic compounds into a water-borne resin blend to form a non-conductive block against heat transfer — independently tested at a thermal conductivity of 0.063 W/mK (ISO 8302 / ASTM C 177). Because it sprays on as a monolithic film, it wraps valves, flanges, and irregular geometry that pre-formed insulation can't seal — and because it's water-based, it flashes its moisture off as steam against the hot surface and cures in minutes per coat.

Where Does HPC Coating Get Used?

Every scenario below comes straight from the manufacturer's typical-use specification.

HPC® Coating — Live Steam Lines

Live Steam Lines

Insulate standard and super-heated steam pipe while it runs. The water-based film steams off and cures in 5–30 minutes per coat — no shutdown, no lost production.

✓ SPI-PUBLISHED
HPC® Coating — Hot Tanks & Vessels

Hot Tanks & Vessels

Control heat loss and protect personnel on tank sidewalls, heads, and skirts up to 800°F with the HPC family.

HPC® Coating — Valves, Flanges & Irregular Geometry

Valves, Flanges & Irregular Geometry

Spray-applied film conforms to the shapes pre-formed insulation can't seal — the classic CUI entry points.

HPC® Coating — Cold Tanks & Lines

Cold Tanks & Lines

Block heat migration into cold tanks, lines, and valves; HPC insulates vessels operating well below freezing once fully cured.

HPC® Coating — Ovens & Exhaust

Ovens & Exhaust

Non-flammable formula rated for oven wall construction and hot exhaust runs — IMO MSC.61(67) smoke & toxicity tested.

HPC® Coating — Marine & Offshore

Marine & Offshore

ABS Marine Approval for shipboard hot-surface insulation where fibrous insulation is unwanted.

Laboratory and field project results may vary according to operating and climate conditions.

How Effective Is HPC Coating? Technical Performance Data

Every number below traces to the current SPI technical data sheets (HPC 3/5/26 · HPC Intermediate 6/11/26).

Thermal Conductivity

0.063 W/mK

ISO 8302 / ASTM C 177 lab-tested at 86°F.

Service Temperature

Up to 800°F

HPC handles surfaces to 390°F (200°C); HPC Intermediate runs 390–800°F with a 900°F temporary peak. Over 800°F, ask about HPC-HT.

Applied Live

No Shutdown

Sprays onto operating equipment. The hotter the surface, the faster each coat steams off and cures — 5–30 minutes per coat.

Non-Flammable

Won't Sustain Flame

Water-based formula will not totally burn — any initial flame burns off surface resin before the film chars and blocks flame. IMO MSC.61(67) tested.

Lightweight

5.2 lbs/gal

72% solids by volume at 5.2 lbs per gallon — a fraction of the dead load of conventional insulation and cladding.

Safe & Certified

USDA · ABS

Non-toxic, lead- and chromate-free, USDA accepted, ABS Marine Approved. Ships non-hazmat.

Does Spray-On Insulation Prevent Corrosion Under Insulation (CUI)?

CUI happens when water gets between conventional insulation and hot steel — the blanket holds moisture against the pipe wall, and the metal corrodes invisibly under the cladding until it fails. A spray-applied ceramic film changes the equation: HPC bonds directly to the substrate as a monolithic layer, leaving no annular gap for water to sit in, no jacketing seams to leak, and no blanket to soak. The coated surface can be visually inspected in service — no cladding removal, no inspection ports, no surprise wall-loss discoveries.

No wet blanket

There is no fibrous material to trap chlorides and moisture against the steel — the classic CUI mechanism is removed, not managed.

Inspectable in service

Damage, discoloration, or film breach is visible on walk-down. Conventional systems hide the steel until the cladding comes off.

Sealed geometry

Valves, flanges, supports, and nozzles — the water-entry points of jacketed systems — get the same continuous film as the straight runs.

Scope: HPC is an insulation coating, not a standalone corrosion barrier: on rusted or corroding steel, prime with Rust Grip® per specification, and topcoat exterior HPC per the application rules below. For below-grade and buried-line CUI strategy, request the technical paper and system specification.

HPC in the Field

Click thumbnails to view full size.

HPC® Coating — Project Image 1HPC® Coating — Project Image 2HPC® Coating — Project Image 3HPC® Coating — Project Image 4HPC® Coating — Project Image 5HPC® Coating — Project Image 6HPC® Coating — Project Image 7HPC® Coating — Project Image 8HPC® Coating — Project Image 9HPC® Coating — Project Image 10HPC® Coating — Project Image 11HPC® Coating — Project Image 12

Application: The Rules That Make or Break an HPC Job

Field guidance from Arin Shahmoradian, USA Distributor — based on SPI application instructions

RULE #1 — MOST IMPORTANT
Exterior HPC must be topcoated. Never leave it exposed to weather.
HPC is lightweight to insulate, which leaves it vulnerable to weathering. Outdoors, overcoat standard HPC with Super Therm® or SP Seal Coat HT (SP Seal Coat HT where the surface faces water splash or weathering up to 390°F). HPC must be completely dry before topcoating. HPC Intermediate is the exception — no topcoat needed outdoors unless a color is specified.
Spray only — and let it steam.
HPC applies by texture sprayer or hopper gun (Graco GTX 2000 EX / Texspray 2000, 6–8 mm nozzle). On hot surfaces: thin priming coat at 50 mils wet, let it steam off (~5 minutes), then build coats of 100–200 mils wet, allowing each coat to completely steam off before the next. Bubbles mean the coat is too thick — puncture and press down.
Rusted steel? Prime with Rust Grip® — and mind the real temperature.
Prime with Rust Grip® where specified. And know this: an IR gun on a bare hot pipe reads heat escaping to atmosphere — once HPC holds the heat back, the surface rises toward the true fluid temperature. Verify valves and components are rated for the actual internal temperature, and spec the product family accordingly.
SURFACES
Metal, concrete, masonry, wood — hot pipes, tanks, valves, ovens. Flat steel: consult SPI first.
FILM BUILD
Built in multiple coats to specified thickness (typically 50–250 mils DFT per the heat-transfer spec).
TEMPERATURE
HPC: apply on 40–390°F surfaces. HPCI: 300–800°F. Above 390°F resins may tan — ceramics keep working.
CURE
Steams off 5–30 min per coat hot; ~4 hrs per coat at 70°F cold. 24 hrs full cure and ≤5% moisture before topcoat.
CLEANUP AND SAFETY
Soap and water. Respirator when spraying; ventilate steam. Store 40–120°F; do not freeze.

If an asset is specified and then a change of assets is made, the new asset must have a comprehensive engineering review before application is allowed. Vibrating or impact-exposed hot pipes use the Multi-Mesh Membrane System between layers per SPI instructions.

Why HPC Outperforms Conventional Insulation

Because Super Therm blocks heat load rather than merely reflecting light, its performance doesn't depend on staying bright white — and because it works at the surface, it reduces the heat that ever reaches the insulation inside your walls.

No Shutdown Required
Sprays onto live, in-service equipment. Heat that ruins other jobs speeds this one up — the hotter the surface, the faster each coat cures.
Kills the CUI Mechanism
Monolithic bond leaves no gap, blanket, or jacket seam for water to sit against hot steel — and the surface stays visually inspectable.
Conforms to Any Geometry
Valves, flanges, elbows, supports — one continuous film where cut-and-fit insulation leaves entry points.
Non-Flammable & Non-Toxic
Water-based, lead- and chromate-free, won't sustain flame, IMO smoke & toxicity tested, USDA accepted. No airborne fibers, ever.
Lightweight
5.2 lbs/gal and 72% solids by volume — insulation without the structural dead load of calcium silicate and metal jacketing.
A System, Not a Silo
Primes with Rust Grip® on corroded steel, topcoats with Super Therm® or SP Seal Coat HT outdoors, and steps up to HPC Intermediate at 390°F+ — one supplier, one spec, one call.

What Certifications and Testing Does HPC Hold?

ISO 8302 / ASTM C 177
Thermal conductivity independently tested at 0.063 W/mK @ 86°F (30°C).
IMO MSC.61(67)
Smoke and toxicity tested for marine and enclosed-space service.
ABS
American Bureau of Shipping Marine Approval.
USDA
Accepted — non-toxic formula for regulated facilities.
★ One Manufacturer, One System

Part of the Award-Winning SPI System

The same manufacturer whose Rust Grip® + Super Therm® + Enamo Grip® system earned the SSPC E. Crone Knoy Award on the Hoover Dam Bypass Bridge builds HPC — and the products are engineered to work together: Rust Grip® primes corroded steel under HPC, and Super Therm® or SP Seal Coat HT weatherproofs it outside.

HPC® Coating - Hoover Dam Bypass Bridge

Purchase HPC Coating. Nationwide Shipping.

Ship HPC and HPC Intermediate anywhere in the United States — non-hazmat standard freight. Talk to Arin Shahmoradian directly for temperature spec, film-build thickness, topcoat selection, and quantities. Monday–Saturday. Authorized SPI Distributor — Volta Coatings.

  • By submitting, you agree to our Terms of Service and Privacy Policy

    Both checkboxes optional — the form submits either way.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

HPC Spray-On Insulation vs. Conventional Insulation vs. Removable Blankets

Attribute HPC® Coating ★ Conventional (calsil / fiberglass + cladding) Removable Blankets
Install while operating Yes — sprays onto live equipment; heat speeds the cure Usually requires shutdown or hot-work planning Yes
CUI risk No annular gap; monolithic bond to the steel Traps moisture against steel — the classic CUI driver Moisture trapped at contact points
Inspection Visual, in service Remove cladding to see the steel Remove blanket
Complex geometry Continuous film over valves, flanges, elbows Cut-and-fit; seams at every transition Pre-fab sizes; gaps at odd geometry
Weight on structure 5.2 lbs/gal, 72% solids by volume Heavy — insulation + metal jacketing Moderate
Fibers / toxicity None — water-based, non-toxic, USDA accepted Airborne fibers during install and removal Varies
Service temperature To 390°F (HPC) / 800°F (HPCI) Varies by product Varies by product
"For hot systems that can't come down, geometry that can't be jacketed, and steel you actually want to see again — spray the insulation on."

What Are the Technical Specifications for HPC?

Vehicle type
Urethane / acrylic blend, water-borne
Solids
49.0% by weight / 72.0% by volume
VOC level
25.1 g/L (0.209 lbs/gal)
Weight
5.2 lbs per gallon
pH
8.5–9.5
Dry time (200–300°F surface)
10–30 minutes per coat, or until steaming has finished
Surface temp — applying
40°F (5°C) min · 390°F (200°C) max
Max surface temp — after cure
390°F (200°C)
Spread rates (minimum)
22.4 ft²/gal @ 50 mils DFT · 11.2 @ 100 · 5.61 @ 200 · 4.5 @ 250
Shelf life
Up to 1 year unopened
Vehicle type
Acrylic / silicone blend, water-borne
Solids
56.5% by weight / 80.0% by volume
VOC level
90 g/L (0.75 lbs/gal)
Weight
5.4 lbs per gallon
pH
8.5
Dry time (390–800°F surface)
5–10 minutes per coat, or until steaming has finished
Surface temp — applying
300°F (149°C) min · 800°F (427°C) max
Max surface temp — after cure
800°F (427°C), temporary peak 900°F (482°C)
Spread rates (minimum)
25.6 ft²/gal @ 50 mils DFT · 12.8 @ 100 · 6.4 @ 200 · 5.1 @ 250
Shelf life
Up to 2 years unopened

Spray application only — texture sprayer (Graco GTX 2000 EX / Texspray 2000) or hopper gun, 6–8 mm nozzle. Surface must be clean of oil, tar, rust, grease, salts, and films: TSP or citrus clean + pressure wash @ 3,500 psi; decontaminate salts to acceptable levels (nitrates 5–10, sulfates 5–10, chlorides 3–5 mcg/cm²); remove pack rust and mil-scale mechanically; prime with Rust Grip® if specified. Mix with a drill and 6" dispersion blade to a creamy, whipped consistency. Hot surfaces: 50-mil wet priming coat, steam off, then 100–200 mil wet coats to spec. Above 390°F the resins may tan or brown at the hot face — the ceramics continue to perform. Respirator required when spraying; ventilate steam. Do not apply in rain, heavy clouds, high humidity, or within 5° of dew point; film must dry before nightfall.

Stop Losing Heat. Keep Running.

Ship HPC anywhere in the United States — spec'd to your surface temperature by Arin Shahmoradian directly.

Ready to Move Forward?

Four ways to engage with Super Therm. Pick the one that fits your project.

HPC Coverage Calculator

Coverage from the TDS minimum spread-rate tables. Film-build thickness is set by your surface temperature and heat-transfer target.

Surface area (ft²)
Product
Target thickness (DFT)
Enter your surface area and select a product and target thickness to see the estimated gallons needed.
Estimates are based on the SPI Technical Data Sheets (TDS) minimum spread rates. Actual coverage may vary depending on surface condition, application method and project requirements. HPC-HT is supplied in 5-gallon pail kits. Contact the technical team to confirm specifications.

Frequently Asked Questions About HPC Coating

Direct answers first — details after. Can't find yours? Call +1 818-696-3786.

Buying & Cost

Where can I buy HPC Coating?

HPC® Coating, HPC® Intermediate and HPC®-HT are sold directly by Volta Coatings, the official USA distributor for SPI Coatings, and shipped nationwide. HPC and HPC Intermediate come in 5-gallon pails; HPC-HT is a two-part kit sold only in 5-gallon pail kits. Order through the purchase form on this page.

Does HPC ship as hazmat?

No. HPC, HPC Intermediate and HPC-HT are water-borne and “not regulated in any capacity of transport” per the SDS, so they ship as standard ground freight with no hazmat surcharge. The only transport restriction is protection from freezing. Shelf life is 1 year unopened (HPC and HPC-HT) and up to 2 years (HPC Intermediate), so order for the job, not the shelf.

How much HPC do I need?

At 100 mils dry film, HPC covers 11.2 ft² per gallon; HPC Intermediate 12.8 ft²/gal; HPC-HT 2.5 ft²/gal at 500 mils (12.5 mm). Typical builds run 50–250 mils for HPC and HPC Intermediate and 500–1,500 mils for HPC-HT, set by the surface temperature and the heat-loss or touch-temperature target. Add 10–15% for overspray with a Texspray 2000, 15–20% with a hopper gun. Use the calculator on this page, then confirm the build for your operating temperature before ordering.

Why use HPC instead of conventional insulation and jacketing?

Three reasons plant engineers give: no corrosion under insulation (CUI), no shutdown, and no jacketing to maintain. HPC bonds directly to the steel as a single monolithic film, so there is no fibrous blanket to soak up water against hot steel and no jacket seams to let water in; the surface stays visually inspectable. It is sprayed onto live, operating equipment. And it carries its own weather barrier when topcoated (Super Therm or SP Seal Coat HT), so there is no aluminum or stainless cladding to dent, pull off or re-band. Material cost per square foot is higher than blanket; installed and lifetime cost is where it wins.
Will it work for my situation?

What temperatures can HPC Coating handle?

Three products cover 40°F to 1,112°F. HPC controls heat transfer on surfaces up to 390°F (200°C). HPC Intermediate covers 390–800°F (427°C) with a temporary peak of 900°F (482°C). HPC-HT, a two-part silicone hybrid, is applied directly to surfaces from about 450°F (232°C) up to 1,112°F (600°C); below about 390°F it will not dry, so standard HPC is used there. Above 390°F the resins in HPC may tan or brown next to the hot face — the ceramics continue to insulate as designed. If your operating temperature changes after coating, contact SPI before putting the asset back in service.

Does HPC prevent corrosion under insulation (CUI)?

HPC removes the mechanism that drives CUI — wet insulation held against hot steel under a jacket — because it bonds directly to the substrate as a monolithic film with no blanket and no seams, and the coated surface stays inspectable. HPC is an insulation coating, not a corrosion coating: where the steel is rusting or will see moisture, prime with Rust Grip® first, and always topcoat exterior HPC so water cannot reach it. That Rust Grip / HPC / topcoat stack is the CUI system.

Can you insulate a pipe while it’s still hot and running?

Yes — that is what HPC is designed for. It is sprayed onto live pipes, tanks and valves with no shutdown: the water flashes off as steam against the hot surface and each coat sets in 10–30 minutes between 200°F and 300°F (HPC) or 5–10 minutes between 390°F and 800°F (HPC Intermediate). The hotter the surface, the faster it cures; HPC-HT in fact must be applied while the surface is hot. The crew works in a respirator and the steam is ventilated.

Is HPC a burn-protection (personnel protection) coating?

Yes. HPC’s thermal conductivity is 0.063 W/m·K (ISO 8302, KU Leuven), so the outer surface of a coated line runs far cooler than the pipe. In an independent food-plant trial on a steam-heated pressure cooker, the bare vessel surface stabilized at about 260°F (127°C); after HPC the surface ran about 140°F (60°C) over the same 45-minute cycle, and steam consumption fell 59%. The usual safe-touch target in a spec is 140°F (ASTM C1055); thickness is engineered to hit it for your operating temperature. Note that an Enamo Grip topcoat over HPC raises the skin temperature by roughly 2–3°C.

Will HPC save energy on steam lines, ovens and tanks?

Yes, and it is measurable. In the pressure-cooker trial above, condensate (steam used) dropped from 5.44 kg to 2.25 kg per cycle — a 59% reduction. KU Leuven’s conductivity measurement gives a calculated 77% cut in heat loss for a 10 cm pipe at 350°C with 1 cm of HPC. Savings on your line depend on temperature, pipe size, thickness and whether the line is indoors; ask for a heat-loss calculation using your numbers.

Can HPC be used on cold tanks and lines?

Yes. The TDS lists HPC “to block heat migration into cold tanks, lines and valves” — it slows heat gain into chilled vessels the same way it slows heat loss from hot ones. On a cold surface there is no steam-off, so each coat is built in stages and allowed to dry fully before the next; drying is measured in hours, not minutes. For sweating chilled-water or refrigerant lines indoors, the goal is to lift the surface temperature above the dew point; tell us the fluid temperature and ambient conditions so the thickness can be set correctly.

What surfaces can HPC be applied to?

Metal, concrete, masonry and wood — hot pipes, tanks, valves, oven walls, exhaust runs and kilns. Surfaces must be clean of oil, tar, rust, grease, salts and films, with salts decontaminated to specification. For flat steel surfaces (tank shells, oven walls), consult SPI first; HPC Intermediate adheres to flat steel directly. Prime with Rust Grip® wherever corrosion is present.
How to apply

How do you apply HPC Coating?

Spray only — a texture sprayer (Texspray 2000 with the flex-head gun) or a hopper gun with a 6–8 mm nozzle. On hot surfaces: a thin priming pass first (the coating will try to “bounce off”; increase distance and air pressure until it bites), let it steam off (about 5 minutes), then build 100–200 mils wet per coat, letting each coat steam off completely before the next. Bubbles mean the coat is too thick — pat them down and apply thinner. Wear a respirator and ventilate the steam. HPC-HT is mixed 9:1 (Part A to Part B) and has a 6-hour pot life.

How thick does HPC need to be?

Thickness is engineered to the surface temperature and the target — heat-loss reduction or a safe-touch surface. Typical HPC and HPC Intermediate specs run 50–250 mils dry, built in several coats; HPC-HT runs 500–1,500 mils (12.5–37 mm) — a 600°C pipe needs roughly 37–60 mm. Apply in multiple coats and finish each selected area before moving on. Send the operating temperature, pipe size and target to SPI for the thickness calculation.

Does HPC need a topcoat?

Outdoors, HPC and HPC-HT must be topcoated — they are lightweight insulating films and cannot be left exposed to weather. Use Super Therm® or SP Seal Coat HT (SP Seal Coat HT where the surface sees water splash or weathering, or where pipes move thermally — it stays flexible), applied only after HPC is completely dry. Indoors, a topcoat is optional. HPC Intermediate is the exception: outdoors it needs no topcoat unless a color is specified. Where a topcoat is used to make the system water-tight, SPI applies it in two coats.

Why does my pipe read hotter after coating?

Because the insulation is working. An IR gun on a bare pipe reads heat escaping to the room; once HPC holds that heat in, the outer face of the steel rises toward the true internal fluid temperature — SPI’s instructions warn that an IR reading of a bare pipe does not tell you the internal temperature. That is also why every valve, part and relief device must be rated for the actual internal temperature before coating, and why a change of asset needs an engineering review.

Will HPC crack when the pipe heats up and cools down?

HPC moves with the steel. In a Southwest Research Institute oven test at 350°C, HPC at 500 mils on carbon-steel coupons showed only hairline cracks, and its estimated coefficient of thermal expansion (about 7.6 × 10⁻⁶ in/in·°F) is close to carbon steel’s. For lines with out-of-norm vibration, cycling or impact from handling, SPI’s Multi-Mesh Membrane is embedded between HPC layers, and SP Seal Coat HT is used as the flexible topcoat. HPC Intermediate’s adhesion is unaffected by cycling from ambient to 800°F.
Proof & safety

What is HPC Coating made of?

 HPC is a water-borne coating that loads specific ceramic compounds into an acrylic resin blend — acrylic/silicone for HPC Intermediate, and a two-part silicone hybrid for HPC-HT — forming a non-conductive block against heat transfer. It is lead- and chromate-free, non-toxic, will not sustain flame, contains no fibers, and is USDA approved.

What’s the difference between HPC and Super Therm?

They solve different heat problems. Super Therm® is a thin (10-mil) exterior ceramic coating that blocks solar heat load on roofs, walls and tanks in the sun. HPC® is a thick-build (50–250 mil) contact insulation for hot equipment — pipes, tanks, valves, ovens — where the heat source is the surface itself. They also work together: Super Therm is one of the approved topcoats that weatherproofs exterior HPC, and on tanks that both lose process heat and gain solar heat, SPI specifies HPC under Super Therm.

Is HPC Coating safe?

Yes. HPC is water-based, will not sustain flame (any initial flame burns off the surface resin, which then chars and blocks it), non-toxic, lead- and chromate-free, USDA approved, and tested to IMO MSC.61(67) for smoke and toxicity — with no airborne fibers, unlike mineral-wool or fiberglass insulation. It carries ABS marine approval. During spray application wear a respirator and ventilate the steam; HPC-HT steam is alkaline and needs a full-face respirator with carbon filter.

How is HPC’s insulation value measured, and can I get the report?

By thermal conductivity, not R-value. KU Leuven’s Laboratory of Building Physics measured HPC at 0.061 ± 0.002 W/m·K by the ISO 8302 heat-flow-meter method (the TDS value is 0.063 W/m·K at 30°C); earlier ASTM C177 guarded-hot-plate tests at VTEC gave 0.076–0.092 W/m·K at a mean temperature of about 200°F. For comparison, mineral wool is roughly 0.04 W/m·K — but HPC is applied in a fraction of the thickness, bonded, with no jacket. Reports are available for submittals.

Need a quantity, a shipped total, or a yes/no on your surface?

Send photos and square footage through the form, or call Volta Coatings (Mon–Fri).

Trusted by Industry Leaders Worldwide

Linde
Chevron
Georgia-Pacific
SpaceX
Petrobras
Engie
US Army
HESS
Vela
Halliburton
Covanta Energy
OXY
ADNOC
Berkshire Hathaway Energy
Nakilat
Milaha
Drydocks World
PEMEX
SASOL
Saipem
Volta Coatings

Official USA distributor of SPI Coatings — Rust Grip®, Super Therm®, Enamo Grip®, HPC® Coating. Nationwide shipping.

Made in USA
Made in USA
Products
Contact Us
Certifications
  • Masdar
  • UL
  • FM Approved
  • Cradle to Cradle
  • DNV
  • USDA